Clock Behavior and Resolution
The clock is a very important component of Channel Recorder. If no clock is present Channel Recorder might fail in performing scheduled, loop or frame accurate recordings.
There are four sources of resolution: input, genlock, configuration and internal.
For clock type GENLOCK, the priority is given in the following order:
-
Input
-
Genlock
-
Configuration
-
Internal
For clock type INPUT, the priority is given in the following order:
-
Input
-
Configuration
Important points to remember are:
-
The resolution from the configuration will only be used when there is no input or genlock signal detected.
-
Internal resolution is only relevant when the following is true:
-
There is another application using Matrox board.
-
The application in question is using a different frame rate family.
-
-
Clock type INPUT is the simplest and should be used unless there is a compelling reason not to use it.
For IP boards 2059 will be used by default.